HIGH POWER® 60W Energy-efficient Fanless Pro Video/Audio Power Supply
|
Technical Specifications
- AC Input Voltage
Maximum Voltage: 264Vac
Normal Voltage : 100~240Vac
Minimum Voltage: 90Vac
- AC Input Frequency
Maximum Frequency: 63Hz
Normal Frequency: 50~60Hz
Minimum Frequency: 47Hz
- Input Current:
1.2A (Max.) @ 115Vac input will full load
0.6A (Max.) @ 230Vac input will full load
- DC Output Power: 5A (60W) Continuous, 70W Peak
- 88% High efficiency design: under normal line input and average of 25%, 50%, 75%, 100% of max load. Minimum efficiency of 89% under 25% load.
- Meet CEC level VI
- No load Power Consumption : Less then 0.21W
- Inrush Current (cold start) : 30A Max. @110Vac/60Hz; 60A Max. @230Vac/50Hz
- AC Leakage Current: 0.25mA Max. @240VAC input.
- Line Regulation: This line regulation is less than ± 5%, of rated output voltage@ full load
- Minimum Load: 0.0A
- Hold Up Time: ≧ 5mSec., @ 115V AC input line, with full load.
- Rise Time: ≦40 milli-second @ 115V AC input with full load - from 10% to 90% of output voltage.
- Turn on Delay Time: The output voltage should rise to 90% of rated output voltage in less than 3 second from 115V AC applied to start up.
Over voltage protection
Short circuit protection
- Over Voltage Protection
100% HI-POT tested: IEC 320 3pin primary to secondary 1800Vac 5mA 1min
100% cycling BURN-IN under 80% load for 2 hours
12V DC output @ +- 5% Standard Deviation
120mV Maximum Ripple Voltage
Operating temperature: 0 - 40 degree C
Storage temperature: -20 - 80 degree C
- Humidity : Operating - 10 to 90 %; Storage - 5 to 90 %
- Altitude : Operating - From sea level to 2,000-Meter ; Storage - 5,000-Meter
- MTBF : > 50,000 hours at full load under 25 degree C ambient condition
- Safety compliance: UL, cUL, TUV, CE, FCC, CCC, KC, GS, CB, DOE VI, cTick, SAA
- Dimensions: 110 (L) * 45 (W) * 26 (H) mm
- DC cable: 20AWG, 1200mm total length
Lead-FREE
Cadium-FREE
Mercury-FREE
Hexavalent chromium-FREE
PBB-FREE
PBDE flame retardants-FREERoHS Compliant - made with hazardous-free components
RoHS is the Restriction Of the use of certain Hazardous Substances in electrical and electronic equipment. This has been a standard in Europe and is now becoming a standard in the world. Not only lead, but cadium, mercury, hexavalent chromium, polybrominated biphenyl (PBB), and polybrominated diphenyl ether (PBDE) flame retardants are limited as well.