Technical Specifications
- AC Input Voltage
Maximum Voltage: 264Vac
Normal Voltage : 100~240Vac
Minimum Voltage: 90Vac
- AC Input Frequency
Maximum Frequency: 63Hz
Normal Frequency: 50~60Hz
Minimum Frequency: 47Hz
- Input Current:
1.2A (Max.) @ 115Vac input will full load.
0.6A (Max.) @ 230Vac input will full load.
- High efficiency design with 87% minimum at normal line input and average of 25%, 50%, 75%, 100% of max load. Meet CEC level V
- No load Power Consumption : Less then 0.5W
- Input Fuse at the hot line side of the input, rating (T2A/250V)
- Inrush Current: Less than or equal to 50A at 115V AC; Less than or equal to 110A at 230V AC at cold start, maximum load.
- Line Regulation: This line regulation is less than ± 1%, of rated output voltage@ full load
- Hold Up Time: ≧ 8.3mSec., @ Normal line, with full load.
- Rise Time: ≦50 milli-second @ rated AC input with full load - from 10% to 90% of output voltage.
- Turn-ON Time: The output voltage should rise to 90% of rated output voltage in less than 3 second from 100V AC applied to start up.
Over voltage protection
Short circuit protection
100% HI-POT tested
100% cycling BURN-IN
12V DC output @ +- 5% Standard Deviation
250mV Maximum Ripple Voltage
Operating temperature: 0 - 40 degree C
Storage temperature: -20 - 80 degree C
- Humidity : Operating - 10 to 90 %; Storage - 5 to 90 %
- Altitude : Operating - From sea level to 2,000-Meter ; Storage - 5,000-Meter
- MTBF : > 30,000 hours at full load under 25 degree C ambient condition
1-Year Express Replacement Advantage Warranty
- Repair or Replace in 3-business Days - |
HIGH POWER® is committed to quality & longevity
|